Sign In | Join Free | My burrillandco.com
Home > Digital Flow Meter >

100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1

Xi'an Xiyi Central Control Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1 from wholesalers
     
    Buy cheap 100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1 from wholesalers
    • Buy cheap 100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1 from wholesalers
    • Buy cheap 100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1 from wholesalers

    100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1

    Ask Lasest Price
    Brand Name : E+H
    Model Number : 5PBB2H
    Price : USD 2400
    Payment Terms : T/T
    Supply Ability : 100 pc
    Delivery Time : 7-14 days
    • Product Details
    • Company Profile

    100% New and Original Automation Equipments Proline Prowirl 5PBB2H-7MF7/0 5PBB2H-AAEADBKP2DEA1K1AA1+AKZ1

    What is it?

    The Proline Promag P 10 is a magnetic (electromagnetic) flowmeter designed for liquid flow measurement in industrial process applications. It uses the electromagnetic principle to measure volumetric flow of conductive liquids.
    Being part of the “Promag P” product line, it is aimed at process applications (especially chemical, corrosive liquids) rather than purely hygienic or water-only uses.

    How it works (Principle of operation)

    • The sensor section has a measuring tube through which the conductive liquid flows.
    • A magnetic field is generated across the flow path; as the liquid flows, a voltage proportional to flow velocity is induced (Faraday’s Law).
    • Electrodes mounted in the flow tube pick up this induced voltage.
    • The transmitter converts it to a flow rate (volume) signal.
    • Because the measurement is based on velocity and cross sectional area, this type of meter is largely independent of fluid density, pressure, temperature and viscosity (within constraints).

    This makes electromagnetic flowmeters highly suitable for a range of liquids where other meter types may struggle.

    Key Specifications & Features

    Here are some of the important specs and features of the Promag P 10:

    Specifications

    • Measurement accuracy (standard): ±0.5 % of reading ± 1 mm/s. Optionally ±0.2 % of reading ± 2 mm/s.
    • Measuring range (volume flow): from about 4 dm³/min (≈ 1 gal/min) up to 9 600 m³/h (≈ 44 000 gal/min) for large sizes.
    • Medium / fluid temperature range:
      • Liner PFA: –20 °C to +150 °C (–4 °F to +302 °F)
      • Liner PTFE: –40 °C to +130 °C (–40 °F to +266 °F)
    • Maximum process pressure: up to PN 40, Class 300, 20K in standard construction.
    • Wetted materials: liner made of PFA or PTFE; electrodes: e.g., stainless steel 316L (1.4435), Alloy C22, tantalum, platinum or titanium.
    • Nominal diameter size range: up to DN 600 (24″) in the sensor version.

    Features & Benefits

    • Bidirectional measurement: can measure flow in both directions (if configured) since principle is velocity-based.
    • No moving parts → low maintenance.
    • Low pressure drop: the sensor does not constrict the flow cross-section (no orifice or throttle), so minimal added pressure loss.
    • Good material flexibility: able to handle corrosive liquids due to choice of liner and electrode materials.
    • Smart usability / diagnostics: includes features such as the “Heartbeat Technology” (for self-diagnostics, verification) and operation via mobile app (SmartBlue) or touchscreen display.
    • Communication / integration: supports HART, Modbus RS485 protocols.
    • Explosion/hazardous-area approvals: available in versions with Ex approvals for hazardous areas.

    Typical Applications

    Given its design and features, Promag P 10 is suited for:

    • Chemical process industry: measuring corrosive or aggressive liquids where materials compatibility matters.
    • Process industries in general: wherever liquids are conductive (a requirement for electromagnetic flow measurement) and density/viscosity/temperature vary.
    • Applications that require robust, low-maintenance flow measurement with minimal insertion loss in the pipe.
    • Situations where remote/transmitter versions and integration into automation systems (HART, Modbus) are required.

    It may be less suited for: non-conductive fluids (since EM flowmeters need conductive media), small line sizes below its specified minimum, very high temperature or pressure beyond its design, or highly abrasive fluids unless special materials are chosen.

    What to Consider when Specifying / Installing

    When selecting and installing a Promag P 10 flowmeter, keep in mind the following:

    • Media conductivity: Ensure the fluid has sufficient conductivity for the electromagnetic principle to work (typical requirement in EM flowmeters).
    • Liner and electrode material selection: Choose liner (PTFE or PFA) and electrode material based on the chemical compatibility of the fluid and temperature.
    • Pipe size (DN) and flow range: Select the correct nominal diameter to match process pipework and expected flow rates – oversizing can reduce accuracy; undersizing may restrict flow or exceed recommended velocity.
    • Process conditions: Maximum temperature, pressure, presence of solids or slurry, fluid density or viscosity variations, installation environment (hazardous area).
    • Installation straight-run / grounding: Although EM meters are less sensitive to some conditions than others, proper installation (grounding, pipe straight runs, absence of strong magnetic fields) still matters.
    • Communication / control integration: If you require HART, Modbus, or remote display/app operation, ensure the correct transmitter variant is chosen.
    • Verification / calibration: Utilize the built-in diagnostic features (Heartbeat Technology) and ensure periodic verification if required by your quality/control regimes.
    • Maintenance & service accessibility: Even though it is low maintenance, consider access for inspection, cleaning (if solids present), and replacement if needed.

    Category

    Specification / Description

    Manufacturer

    Endress+Hauser

    Model

    Proline Promag P 10

    Type

    Electromagnetic flowmeter

    Measuring principle

    Faraday’s law of electromagnetic induction

    Measured variable

    Volumetric flow rate of conductive liquids

    Typical applications

    Chemical process industry, corrosive/acidic liquids, industrial process fluids

    Nominal diameters (DN)

    Up to DN 600 (24″)

    Flow range

    Approx. 4 dm³/min – 9 600 m³/h (depends on size)

    Accuracy (standard)

    ± 0.5 % of reading ± 1 mm/s

    High-accuracy option

    ± 0.2 % of reading ± 2 mm/s

    Fluid temperature range

    PTFE liner: –40 °C to +130 °CPFA liner: –20 °C to +150 °C

    Process pressure (max)

    Up to PN 40 / Class 300 / 20K

    Wetted materials

    Liner: PTFE or PFAElectrodes: 316L SS, Alloy C22, Tantalum, Titanium, or Platinum

    Flow direction

    Bidirectional

    Process connections

    Flanged (various standards)

    Housing protection

    Typically IP66/67 or NEMA 4X

    Communication interfaces

    HART, Modbus RS485

    Diagnostics

    Heartbeat Technology (self-monitoring and verification)

    Display / Operation

    Local display or remote transmitter; SmartBlue App support

    Power supply

    24 V DC or 85–260 V AC (depending on version)

    Approvals / Certifications

    Available with Ex (hazardous area) approvals

    Mounting style

    Inline, with grounding rings or electrodes

    Main advantages

    No moving parts, low pressure loss, corrosion-resistant, easy integration, low maintenance

    Limitations

    Requires conductive fluid (> ~5 µS/cm); not suitable for non-conductive liquids or gases