Sign In | Join Free | My burrillandco.com
Home > Industrial Pressure Transmitters >

100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement

Xi'an Xiyi Central Control Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
     
    Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
    • Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
    • Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
    • Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
    • Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
    • Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers
    • Buy cheap 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement from wholesalers

    100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement

    Ask Lasest Price
    Brand Name : XIYI
    Model Number : 3151SH
    Price : $400.00 - $600.00/pieces
    Payment Terms : T/T
    Supply Ability : 100 pc 1 week
    Delivery Time : 7-14 days
    MOQ : 1
    • Product Details
    • Company Profile

    100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement

    100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement

    The pressure of 0 to 31.02MPa on either side of the transmitter will not cause damage, and it meets the performance requirements when working within the static pressure range of 3.45kPa to 31.02kPa.

    Accuracy: 0.075%, turndown ratio 100:1

    Differential pressure: calibration range from 0.125kPa to 6890kPa

    Gauge pressure: calibration range from 0.125kPa to 41370kPa

    Absolute pressure: calibration range from 0.374kPa to 6890kPa

    Process Isolation Diaphragms: Stainless Steel, Hastelloy C-276, Monel, Tantalum

    Compact design, durable and easy to install

    Negative pressure can be measured

    working principle:

    The measured pressure is converted into a capacitance variable by a capacitive sensitive element, directly converted into a digital signal by the A/D circuit, and sent to the microprocessor after conversion. To display/adjust the instrument or DCS and other devices. The communication line converts the measured pressure digital signal from the microprocessor into a frequency signal and superimposes it on the 4~20mADC analog signal, which is received by the corresponding HART terminal equipment.

    Features:

    ·High stability and reliability

    The high-sensitivity pressure-sensitive element is a fully sealed design, and the stress isolation structure and overvoltage self-protection ensure the stability and reliability of the sensitive element.

    ·Automatic compensation function

    The correction coefficients of pressure and temperature characteristics stored in the EEPROM are used for the main control unit microprocessor to perform linear and temperature automatic compensation, so that the 3151 intelligent transmitter has high precision and little influence of temperature.

    ·Digital communication, data storage

    HART Communicator communication enables remote setting, monitoring and diagnosis. And the set configuration data is stored in the non-volatile EEPROM of the circuit board, and these data will not be lost after the power is turned off. Power cycle the transmitter to resume operation immediately.

    ·Five-digit LCD output display

    The five-digit LCD indicator can display the digital reading of the measured pressure (including engineering units, such as: kPa, kgf/cm, mbar, mmH2O, etc.), the percentage of the range (%) and the output current (mA).

    ·Configuration protection

    In order to prevent the configuration data of the transmitter from being changed arbitrarily, the stored data can be locked through the protection switch.

    ·Local zero and span adjustment

    The S and Z buttons of the main control unit are used by the user to adjust the zero point and span of the transmitter without a configuration device.

    ·Explosion-proof mark

    The explosion-proof type of the instrument includes intrinsic safety (Ex ia IIC T5) and flameproof type (Ex d IIC T5), both of which have passed the national explosion-proof standard certification.

    · Strong interchangeability of parts

    Regardless of the range and output form, the flanges, joints, electrical housings, display heads, end caps and mounting brackets can be interchanged, the smart circuit boards can also be interchanged, the sensors can also be interchanged, and can also be changed by replacing the sensor. measuring range, but recalibration is also required after replacement.

    Quality 100 1 Turndown Ratio Pressure Transducer for Safe and Accurate Pressure Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xi'an Xiyi Central Control Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)